Quick Details
- Place of Origin: Busan, South Korea
- Brand Name: Physiograph
- Model Number: Physiograph P400
Packaging Details | Box |
---|---|
Delivery Time | 1 month |
Physiograph P400 [8ch. biosignal measuring instrument] |
Main Features
< Base Module >
< Biosignal Measuring Module >
Specifications
Bio-Amp |
Biosignal |
Specification |
Amplification (basic x selectable) |
ECG, EOG, EMG |
basic : 500 selectable : x1, x2, x5 |
EEG |
basic : 25,000 selectable : x1, x2, x5 |
|
Filter set |
ECG |
Notch Filter : 60, 120Hz or 50, 100Hz HPF : 0.3Hz LPF : 35Hz |
EOG |
Notch Filter : 60, 120Hz or 50, 100Hz HPF : 0.1Hz LPF : 20Hz |
|
EMG |
Notch Filter : 60, 120Hz or 50, 100Hz HPF : 10Hz LPF : 200Hz |
|
EEG |
Notch Filter : 60, 120Hz or 50, 100Hz HPF : 3Hz LPF : 40Hz |
ECG-Amp |
Specifications |
|
Record Mode |
ECG Wave, Beat, BPM |
|
Amplification (basic x selectable) |
basic |
500 |
selectable |
x1, x2, x5 |
|
Filter Set
|
Notch filter |
60 Hz or 50 Hz |
HPF |
0.3 Hz |
|
LPF |
35 Hz |
|
Measuring range |
BPM |
40~240 BPM |
PPG-Amp |
Specifications |
|
Record Mode |
PPG Wave, BPM, PTT |
|
Amplification (basic x selectable) |
basic |
315 kV/A |
selectable |
x1 ~ x20 (continuously) |
|
Filter Set
|
Notch filter |
60 Hz or 50 Hz |
HPF |
0.1 Hz |
|
LPF |
10 Hz |
|
Measuring Range |
BPM |
40 ~ 240 BPM |
PTT |
100 ~ 500 ms |
Bridge-amp |
Specifications |
|
Amplification (basic x selectable x fine adjustable) |
basic |
500 |
selectable |
x1, x5, x25 |
|
fine adjustable (Volume) |
x1 ~ x3.5 (continuously) |
|
Filter Set
|
Notch filter |
60 Hz or 50 Hz |
HPF |
DC, 0.1, 0.3 Hz |
|
LPF |
20, 50, 100 Hz |
|
Other |
Auto balancing function (auto-zero) |
EDG-Amp |
Specifications |
|
Record Mode |
SCR, SCL |
|
Amplification (basic x selectable x fine adjustable) |
basic |
80 kV/A |
selectable |
x1, x2, x5 |
|
fine adjustable |
x1 ~ x6 (continuously) |
|
Filter Set
|
SCR |
HPF : 0.05 Hz LPF : 1 Hz |
SCL |
LPF : 1 Hz |
Buffer-amp |
Specifications |
|
Record Mode |
Notch On / Off |
|
Amplification (basic x selectable x fine adjustable) |
basic |
0.1 |
selectable |
x1, x10, x100 |
|
fine adjustable |
x1 ~ x11 (continuously) |
|
Filter Set
|
Notch filter |
60 Hz or 50 Hz |
HPF |
DC, 0.1, 0.3 Hz |
|
LPF |
20, 50, 100 Hz |
iDAQ-400 |
Specifications |
Base module |
iDAQ-400 |
Biosignal measurement module (Amp module) |
Bio / ECG / PPG / Bridge / EDG / Buffer – Amp (For more details, see the specification of each Amp module) |
Sampling rate |
1 ~ 2,000 samples/sec |
Data resolution |
12 bit |
Measurement signal range |
Internal input signal is different by Amp module External input signal is ±5V. |
Signal amplification range |
Frequency range and amplification degree of measured signal are different by Amp module |
Size(W×L×H) |
112×200×32 mm (Only for individual Amp modules) All the module that make up the P400 system are in the same size. |
Power |
12V / 2A (adaptor) (power by each Amp module) |
Computer requirement (Minimum requirement) |
CPU: 600MHz or higher, RAM: 64 MB or higher OS: Windows XP/Vista or higher |
Notice
The person in charge
Telephone
Fax
82-0513252869Address
, 부산광역시,0 / 4000
At least 10~1000 characters.
0/ 1000