Usage Environment
1. Usage water quality: Tap water, drinking water.
2.Usage water Temperature: 0∼40℃
3. Usage Water Pressure Range:: 0.5 ∼ 8Kgf/cm²
4. Usage temperature Range:0∼40℃
5. Usage Humidity Range: under 90%RH
6. Storage Temperature Range:-20∼60℃
7. Storage Humidity Range: Under 95%RH
8. Sealing Performance: No water drop and breakage when water pressure is reached at 15Kgf/cm² for 1 minute as working voltage is turned OFF
9.Max. withstand againt water pressure: No water drop and breakage when water pressure is reached at 50Kgf/cm² for 1 minute as working voltage is turned OFF
Specification
1. Rated Voltage: DC 12V ±15%
2. Voltage Consumption: less than 800mA
3. Insulation Grade: E
4. Insulation Resistance: DC500VM above -100MΩ
5. Insulation Internal Pressure: AC1500V leakage reactance 5mA in one second
6. Power On Hours: Controlling
7.Full-Voltage starting: working when it be pressured by 8Kgf/cm² in rated voltage -15%