Introduction
● Dimension: Ø12” * 1,500mm
● Heat Flux: 25,000 Kcal/ Hr
● Design Pressure, Shell/ Tube: 3.0/ 3.0 Kg/ Cm2G
● PCW In/Out Temp. : 18/25 ℃
● PCW Rate Required: 50LPM (13.2GPM)
● DSP Chemical Volume: 1,000 Liter (265 Gallons)
● DSP Chemical In/ Out Temp. : 42/ 23℃
● Cooling Time: 30 Min.
● Tube Side △P: 0.2Kg/ Cm2G @20LPM
● Shell Side △P: 0.5Kg/ Cm2G @50LPM
● Heat Exchanger Data
Specification
- Heat Transfer Area: 13m2
- LMTD: 16℃
- Heat Transfer Coefficient: 120 Kcal/m2 Hr ℃
Should you require further information on our products or services, please send us an email or visit our website.
The person in charge
Telephone
82-0316770870Fax
031-677-0877Address
San 67-5, Kangduk-ri, Miyang-myun, Anseong-si, Kyeonggi-do, South Korea, 경기도,0 / 4000
At least 10~1000 characters.
0/ 1000