Go to body Contents
Unbranded

Refrigeration unit

  • Payment
    T/T
  • MOQ
    Negotiable
  • Country of sale
    World Wide
  • PRICE
    • FOB

      Depend on quantity

Trade Assurance Service

ITEM SPECIFICS

  • Brand
    Unbranded
  • origin
    Republic of Korea
  • Size(Capacity)

Introduction

Korea tech refrigeration unit is a cooling system with the best design of

fresh and frozen application on truck

The road compressor is directly operated by the vehicle's engine.

split system ( condenser and evaporator are separate)

 

RX-100

 

Description

The RX-100 Thermo Rex refrigeration unit is a cooling system with the best design of fresh and frozen application on small truck.

The road compressor is directly operated by the vehicle's engine.

Split system (condenser and evaporator are separate)

 

Refrigerant

HFC R-134a or R-404A

Chlorine - Zero

Refrigerant charge - 1.9kg / 4.2Ibs (R-404A)

Ozone depletion potential "Zero"with the new refrigerant

Refrigerant flow rate - 1.6kg

 

Comperssor(Engine Driven)

SD-5L14-5-cylinder 138cc

TM-15HS -6-cylinder 147cc(option)

 

Evaporator

PLATE FNI TYPE

Turbo Fan nr.1 diam. 250mm - 955m3/h

Optimal use of high- performance turbo-fan effect of the frozen

Use a large load space Slim Evaporator

 

Condenser

PLATE FIN TYPE

Electrofan nr.2-diam. 250mm

Corrosion-resistant and environmentally friendly material ABS external use

 

Defrost

Automatic hot gas defrost

 

Totla current consumption

DC 12V - 26Amp

DC 24V -(OPTION)

 

Dimensions & Weight

 

 

 

 

 

 

Height

Width

Depth

Ibs

kg

Condenser

11.2 in(285mm)

40.1 in(1020mm)

17.9 in(455mm)

60.3

27.3

Evaporator

7.3 in (185mm)

39.8 in(1010mm)

22.8 in(580mm)

43.8

19.8

 

Refrigeration Capacity

 

 

 

 

 

 

Evaporator return

air temperature

HFCR-404Arefrigerant

HFC R-134a refrigerant

Road Operation

Road Operation

˚C

˚F

Kcal/h

Watts

Btu/h

Kcal/h

Watts

Btu/h

0

32

2597

3020

10298

1788

2080

7092

-18

-0.4

1702

1980

6751

1173

1365

4654

-25

-13

1328

1545

5268

-

-

-

 

RX-120

 

Description

The RX-100 Thermo Rex refrigeration unit is a cooling system with the best design of fresh and frozen application on small truck.

The road compressor is directly operated by the vehicle's engine.

Split system (condenser and evaporator are separate)

 

Refrigerant

HFC R-134a or R-404A

Chlorine - Zero

Refrigerant charge - 1.9kg / 4.2Ibs (R-404A)

Ozone depletion potential "Zero"with the new refrigerant

Refrigerant flow rate - 1.6kg

 

Comperssor(Engine Driven)

SD-5L14-5-cylinder 138cc

TM-15HS -6-cylinder 147cc(option)

 

Evaporator

PLATE FNI TYPE

Turbo Fan nr.1 diam. 230mm - 1120m3/h

Eva fan 2 with optimal effectt of frozen

Use a large load space slim Evaporator

 

Condenser

PLATE FIN TYPE

Electrofan nr.2-diam. 250mm

Corrosion-resistant and environmentally friendly material ABS external use

 

Defrost

Automatic hot gas defrost

 

Totla current consumption

DC 12V - 24.9Amp

 

Dimensions & Weight

 

 

 

 

 

 

Height

Width

Depth

Ibs

kg

Condenser

11.0 in(280mm)

39.8 in(1010mm)

16.6 in(420mm)

51.5

23.3

Evaporator

7.1 in (180mm)

39.6 in(1006mm)

23.2 in(590mm)

42.7

19.3

 

Refrigeration Capacity

 

 

 

 

 

 

Evaporator return

air temperature

HFCR-404Arefrigerant

HFC R-134a refrigerant

Road Operation

Road Operation

˚C

˚F

Kcal/h

Watts

Btu/h

Kcal/h

Watts

Btu/h

0

32

2675

3210

10620

1842

2210

7312

-18

-0.4

1754

2105

6964

1210

1452

4804

-25

-13

1367

1640

5427

-

-

-

 

RX-250

 

Description

The RX-250 Thermo Rex refrigeration unit is a cooling system with the best

design of fresh and frozen application on small truck.

The road compressor is directly operated by the vehicle's engine.

Split system (condenser and evaporator are separate)

 

Refrigerant

HFC R-134a or R-404A

Ozone protection, non CFC 404a

Refrigerant charge - 2.3kg±100g / 5.1Ibs (R-404A)

 

Comperssor(Engine Driven)

Sanden SD-7L14-7-cylinder 154.9cc

Tama TM-16HS -6-cylinder 163cc(option)

OIL-Separator (Basic Specifications)

 

Eva.Airflow volume

DC motor driven two fan system evaporator

turbo fan 2 by DC motor opeation

Airflow : 1890m3/hr 2-Fan(Dual)

Velocity : 7.8m/s

 

Condenser

PLATE FIN TYPE & PF-Type(Muti Flow)- Option

Electrofan nr.2-diam. 280mm

 

Defrost

Automatic hot gas defrost

 

Totla current consumption

DC 12V - 20.3Amp

 

Dimensions & Weight

 

 

 

 

 

 

Height

Width

Depth

Ibs

kg

Condenser

14.5 in(370mm)

35.8 in(1010mm)

13.0 in(420mm)

 

 

Evaporator

7.3 in (185mm)

49.6 in(1006mm)

23.2 in(590mm)

 

 

 

RS-500S

 

Good point

Environment friendly and advanced freezing performance with cost effciency

Increase durability by one-piece frame design.

Designed for convenient maintenance.

Designed considering durability and aerodynamic.

Maximum efficiency in short period of ime by using eva. fan

Durability and power transition has been increased by using 3vx belt during high

speed driving.

 

 

Engine

Open Type Compressor

Model

Yanmar3TNE-74HT/Japan

BOCKFKX40-470TK/Germany

Number of cylinders

3

4

Displacement

1006cc

465cc

Oil charge

7.2L

2.0L

 

Refrigeration Capacity

 

 

 

 

 

 

Engine Power

Electric Power

R404A

0˚C

-20˚C

-29˚C

0˚C

-20˚C

-29˚C

Watts

7815

5857

4267

6824

5124

3734

Kcal/h

6708

5027

3662

5857

4398

3205

But'h

26619

19950

14534

23244

17453

12718

 

Control system

Automatic engine operation based on fixed temperature.(manual model)

 

Temperature regulator display.(engine glow & start m/c, battery, coolant engine oil)

 

Convenient 2-channel temperature(normal/low)adjustment function

 

Engine operation time check funciton

 

Low and high engine speed adjustment function.

 

Checks machine problem in advance by applying system mode.

 

Eva. Airflow volume

DC motor driven three fan system evaporator

Airflow : 3740m3/hr

Velocity : 8.6m/s

 

Defrost

Mnaual defrost : User manually press defrost button

Auto defrost : Automatically defrost by using air switch (diff. pressure)

Timer defrost : Automatically defrost by entering defrost cycle &time into

control switch

 

Systme protection devices

Engine low oil pressure cutout.

Engine coolant high temperature cutout

Refrigerant high temperature cutout

Compressor body high temperature cutout.

 

Refrigerant

Ozone protection. non CFC 404A(Ozone depletion potential "Zero"with the new refrigerant)

Refrigerant flow rate :4.1kg±100g

PAYMENTS DETAILS

This supplier supports payments for offline orders
  • Telegraphic Transfer : T/T
Contact Payment Manager
  • Name : Park Tae gun
  • Tel : 82-0415778991
  • Email : sunhui@koreatechco.co.kr

SHIPPING

Shipping from : Republic of Korea
  • Mijuk-ri, Pungse-myeon, Cheonan Si, Chungcheongnam-do 330-911, Korea, 경기도,
Can't find a valid Shipping method for supplier account. Please contact the pertaining representative for detailed information.
koreatech

koreatech

Seller_Mail
  • The person in charge

  • Telephone

    82-0415778991
  • Fax

    041-577-8910
  • Address

    Mijuk-ri, Pungse-myeon, Cheonan Si, Chungcheongnam-do 330-911, Korea, 경기도,
  • Business Type :
    Manufacturer
  • Main Product :
  • Established :
    2008

CUSTOMER QUESTIONS & ANSWERS

0 / 4000

질문이 없습니다.

CUSTOMER REVIEWS (0)

At least 10~1000 characters.

0/ 1000

COMPARISON TO SIMILAR ITEMS more

  • No Items
supplier level
GOLD GOLD
koreatech Seller's Store
Seller's Store url
  • Response Level
      41% ~ 50%
  • Supplier Level
      Less than 100 million (KRW)
  • Transaction Level
      less than 5
SUPPLIER BEST
  • No Items