Air Source Heat Pump
Product Overview
A system that utilizes the external air for the heat pump to provide heating and hot water
Air Source Heat Pump
The system utilizes 60-80% air and 25% of electricity to provide heat thereby reducing the electricity cost.
Features
Application
Specification of Air Source Heat Pump(IAW-16A Series)
Model
|
IAW-16A-09
|
IAW-16A-13
|
IAW-16A-17
|
IAW-16A-25
|
|||
Capacity
|
Heating
|
KW
|
30.29
|
44.51
|
60.59
|
88.7
|
|
Kcal/h
|
26,053
|
38,275
|
52,106
|
76,279
|
|||
USRT
|
8.62
|
12.66
|
17.23
|
25.22
|
|||
Power Supply
|
KW
|
12
|
15
|
24
|
36
|
||
Power Supply
|
3Phase x 380V x 60Hz
|
||||||
Dimension
|
Length
|
mm
|
2,040
|
2,340
|
2,340
|
3,480
|
|
Height
|
1,240
|
1,340
|
1,570
|
2,000
|
|||
Depth
|
710
|
710
|
1,100
|
1,030
|
|||
Compressor
|
Type
|
Scroll type
|
|||||
Quantity
|
1
|
2
|
|||||
Operation Method
|
Direct-on-line
|
||||||
Volume Control
|
%
|
0~100%
|
|||||
Refrigeration Ton
|
RT
|
4.32
|
5.6
|
8.64
|
12.52
|
||
Refrigerant
|
Type
|
R-410A
|
|||||
Control Method
|
Thermostatic expansion valve
|
||||||
Condenser
|
Type
|
Brazed Plate type
|
|||||
Circulation Volume
|
LPM
|
11
|
16
|
22
|
32
|
||
Piping(IN/OUT)
|
A
|
25
|
25
|
40
|
50
|
||
Outdoor unit
|
Type
|
Finned Copper Tube Type
|
|||||
Thermal Storage Area
|
m2
|
108.5
|
128.2
|
186.5
|
330.3
|
||
Fan & Motor
|
Air
Volume |
m3/min
|
190
|
240
|
510
|
680
|
|
Size
|
Ø
|
450x3
|
500x3
|
630x3
|
630x4
|
||
Control
|
Temperature Control
|
4way proportional control valve
|
|||||
Operation Control
|
PCB
|
||||||
Defrosting
|
Hot Gas
|
Reverse Cycle
|
|||||
Weight
|
kg
|
350
|
500
|
650
|
750
|
||
Conditions for the products
|
heating
|
Outdoor (DB7°C); Temp of water supply to be 30°C; Temp of output water to be 70°C;
![]() |
|||||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
Specification of Air Source Heat Pump(IACH-16B, IACHK-16C series)
Model
|
IACH-16B-10
|
IACH-16B-13
|
IACH-16B-21
|
IACH-16B-28
|
IACHK-16C-39
|
|||
Capacity
|
Heating
|
KW
|
36.16
|
45.7
|
71.44
|
96.74
|
137.21
|
|
Kcal/h
|
31,100
|
39,300
|
62,300
|
83,200
|
118,000
|
|||
USRT
|
10.28
|
13
|
20.6
|
27.51
|
39.02
|
|||
Cooling
|
KW
|
34.77
|
42.21
|
69.65
|
88.37
|
122.09
|
||
Kcal/h
|
29,900
|
36,300
|
59,900
|
76,000
|
105,000
|
|||
USRT
|
9.89
|
12
|
19.81
|
25.13
|
34.72
|
|||
Power Supply
|
Heat/Cool
|
KW
|
13.5/12.9
|
17.0/16.2
|
25.3/24.8
|
37.4/36.2
|
60.0/55.0
|
|
Power Supply
|
3Phase x 380V x 60Hz
|
|||||||
Dimension
|
Length
|
mm
|
2,040
|
2,380
|
2,334
|
3,480
|
2,680
|
|
Height
|
1,270
|
1,370
|
1,600
|
2,000
|
2,290
|
|||
Depth
|
710
|
730
|
1,110
|
1,110
|
2,030
|
|||
Compressor
|
Type
|
Scroll type
|
Screw
|
|||||
Quantity
|
1
|
2
|
1
|
|||||
Operation Method
|
Direct-on-line
|
Y-
![]() |
||||||
Volume Control
|
%
|
0~100%
|
||||||
Refrigeration Ton
|
RT
|
4.12
|
4.92
|
8.24
|
12.35
|
17.35
|
||
Refrigerant
|
Type
|
R-22
|
R-407C
|
|||||
Control Method
|
Thermostatic expansion valve
|
|||||||
Condenser
& Evaporator
|
Type
|
Brazed Plate type
|
||||||
Heating
Circulation Volume |
LPM
|
104
|
131
|
208
|
277
|
393
|
||
Cooling
Circulation Volume |
100
|
121
|
200
|
253
|
350
|
|||
Piping(IN/OUT)
|
A
|
25
|
25
|
40
|
50
|
65
|
||
Outdoor unit
|
Type
|
Finned Copper Tube Type
|
||||||
Thermal Storage Area
|
m2
|
108.5
|
128.2
|
186.5
|
330.3
|
522.6
|
||
Fan & Motor
|
Air
Volume |
m3/min
|
190
|
240
|
510
|
680
|
1,080
|
|
Size
|
Ø
|
450x3
|
500x3
|
630x3
|
630x4
|
700x6
|
||
Control
|
Temperature Control
|
4 way proportional control valve
|
||||||
Operation Control
|
PCB
|
|||||||
Defrosting
|
Hot Gas
|
Reverse Cycle
|
||||||
Weight
|
kg
|
400
|
550
|
700
|
800
|
1200
|
||
Conditions for the products
|
heating
|
Outdoor (DB7°C); Temp of water supply to be 40°C; Temp of output water to be 45°C;
|
||||||
cooling
|
Outdoor (DB25°C); Temp of water supply to be 12°C; Temp of output water to be 70°C;
|
|||||||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
Air Source Heat Pump Water Heater(IAT-16A-01) & EVI Air Source Heat Pump(IAH-16A-05)
Model
|
IAT-16A-01
|
IAH-16A-05
|
|||
Capacity
|
Heating
|
KW
|
2.8
|
17
|
|
Kcal/h
|
2,408
|
14,620
|
|||
USRT
|
0.79
|
4.83
|
|||
Power Supply
|
KW
|
0.88
|
6.8
|
||
Power Supply
|
Single x 220V x 60Hz
|
3Phase x 380V x 60Hz
|
|||
Dimension
|
Length
|
mm
|
568
|
1,108
|
|
Height
|
1,670
|
1,075
|
|||
Depth
|
568
|
568
|
|||
Compressor
|
Type
|
Scroll type
|
EVI Scroll type | ||
Quantity
|
1
|
1 | |||
Operation Method
|
Direct-on-line
|
||||
Volume Control
|
%
|
0~100%
|
|||
Refrigerant
|
Type
|
R-410A
|
|||
Control Method
|
Thermostatic expansion valve
|
||||
Condenser
|
Type
|
Brazed Plate type
|
|||
Circulation Volume
|
LPM
|
1.1
|
5.1
|
||
Piping(IN/OUT)
|
A
|
20
|
25
|
||
Outdoor unit
|
Type
|
Finned Copper Tube Type
|
|||
Thermal Storage Area
|
m2
|
0.36
|
1.09
|
||
Fan & Motor
|
Air
Volume |
m3/min
|
8.3
|
83
|
|
Size
|
Ø
|
153
|
460
|
||
Tank Capacity
|
L
|
190L built-in type(STS)
|
Separate installation
|
||
Control
|
Temperature Control
|
4way proportional control valve
|
|||
Operation Control
|
PCB
|
||||
Defrosting
|
Hot Gas
|
||||
Weight
|
kg
|
67
|
200
|
||
Conditions for the products
|
heating
|
Outdoor (DB20°C, WB15°C); Temp of water supply to be 15°C; Temp of output water to be 55°C
|
Outdoor (DB7°C, WB6°C); Temp of water supply to be 7°C; Temp of output water to be 55°C; T=48°C
|
||
The above specification may vary depending on the site and temperature conditions. The above specification may change without prior notice for further improvement. |
The person in charge
Address
Sincheon-ri, Hallim-myeon, Gimhae Si, Gyeongsangnam-do 621-873, Korea, 경상남도,Please enter the text on the left image to prevent automatic input.