② One equipment provides such functions that are required to perform an operation as Functional Cutting (Pure Cut,
Blend1, Blend2, Blend3), Coagulation (Spray Coagulation, Contact Coagulation), Bipolar Coagulation (Bipolar Cut,
Hand Bipolar, Foot Bipolar).
③ Two Twin Button Handles provide remote-control function. (Select Cutting or Coagulation)
④ Foot Switch is available for Cutting and Coagulating.
⑤ Hand Bipolar(Auto Bipolar) can be used only by contacting Forceps.
⑥ Microprocessor can straighten, stabilize the output.
⑦ Operations of Cutting, Coagulation and Bipolar Coagulation can be distinct from each other by sound and indication lamp.
⑧ Each application mode (Cutting, Coagulation, Bipolar Coagulation) has a different sound, which enables you to easily
distinguish an operation type.
⑨ If the area between a patient and the pad is not appropriate, REM(Return Electrode Monitoring) gives the alarm with a
warning sound and stop an operation of the product to prevent a burning incident.
⑩ Holding the button for each mode for more than 3 seconds, the output ratio on Display will be changed to 1W to be
facilitated to shift from the low to high output.
⑪ The level of alarm sound can be adjusted during an operation of application mode.
⑫ The selected output ratio of Cut, Coagulation, and Bipolar Coagulation will displayed by reenergizing the device after
power OFF.
⑬ 10 storages are available by using user storage function.
⑭ The input power frequency 50Hz / 60Hz is automatically detected.
⑮ It can be used by selecting the monopolar output (M1, M2).
⑮ It can be used by selecting the monopolar output (M1, M2).
⑯ It can be used in liquid (Urosol Solution).
Safety Function
① A fuse built in a power circuit prevent an over current from flowing through the equipment.
② When the plate attached to the patient is separated from the equipment, the red alarm light begins flickering.
Pressing the button of Twin Button Handle or the pedal of Cutting and Coagulation of Double Foot Switch will stop the alarm sound and the equipment.
③ REM (Return Electrode Monitoring) monitors the size of contacting area between a patient and the pad. If the size is inappropriate,
it automatically blocks the high- frequency current to minimize the danger of burning incidents.
④ To protect a patient, the case is fully grounded so that a leakage current can flow into the earth.