Go to body Contents
Unbranded

Infant Incubator

  • Payment
    T/T
  • MOQ
    Negotiable
  • Country of sale
    World Wide
  • PRICE
    • FOB

      Depend on quantity

ITEM SPECIFICS

  • Brand
    Unbranded
    Model CHS-i1000
  • origin
    Republic of Korea
  • Size(Capacity)

Infant Incubator(CHS-i1000)

Introduction

The new CHS-i1000 Infant Incubator allows create optimal conditions through precise control of hood temperature and humidity by use of microprocessor. Double walls are also adopted to minimize radiant heat loss and such effect of external heat loss on infants.

By use of microprocessor, CHS-i1000 makes it possible to control temperature and humidity of the hood inside precisely. It is designed that air circulation system minimizes the heat loss in the hood by use of double wall structure and air wall(curtain). Humidity can be adjusted between 30~90% with a humidity controller. 8types of audible & visible alarm devices enable users to identify problems of the infant or Incubator easily, if the incubator has some trouble in its operation. Double safety device makes overheat of heater cannot affect the safety of the infant. In order to provide comfortable and silent environment for the infant, the noise level of the CHS-i1000 Infant Incubator is programed to lower than 47dB(A), which is lower than IEC601-2 standard.

 

 

Features

Simultaneous Care for Multiple birth
Multiple births have escalated over the years. Recent clinical studies observed the possibility of inhibited growth with premature twins suffering from separation trauma.
The new CHS-i1000 allows you to simultaneously monitor your low birthweight twin infants in one incubator. A large mattress allows the clinician the sufficient spaces for caring both babies and provides enough room for both infants to grow comfortably.
 

 

Double Wall
Consistent air temperature is imperative to the development of a premature baby.
The CHS-i1000 infant incubator adopts Double Wall Structure to minimize radiant heat loss from the newborn baby skin and maintain air temperature at constant level by flowing warm air between inner wall and outer wall during the operation.
Inner wall is designed to be detached easily from the main hood for cleaning the inside of the hood and sterilization.

 

Sensor Box
The controller module of the CHS-i1000 receives the data such as air temperature, skin temperature, humidity from the Sensor Box. These data are displayed on large LEDs of the control panel.
The connector and skin sensor is easily detached from the sensor box when cleaning or sterilizing the incubator hood.

 

Air Wall(Curtain)
Air wall(Curtain) is incorporated into the new CHS-i1000 to help reduce temperature fluctuation within the incubator when the front door is opened for treatment of infant.

 

Humidity Control and Display
Humidity of the hood inside can be controlled until it reaches to the setting value and the range of the humidity control is between 30%~90%. The generated humidity is supplied to the hood by air circulation system. The measured value is displayed on the humidity display window.
The display range is between 30%~90% and if humidity is lower than 30% or higher than 90%, LL or HH is indicated on the humidity display window.

 

Alarm function for safety
Power Fail. : When the power is off or disconnected accidently.
System Fail. : When the system error occurs.
Over Temp. : When the air temp. is over maximum control range(37..) by 1...
Air Flow : In case of non-operation of fan & motor.
Sensor Fail. : The sensors are disconnected or the wire of the sensors is broken.
Air Temp. : When the air temp. differ from setting temp. by over 1.5..or lower 3..
Skin Temp. : When the real skin temp. differ from setting temp. by over 1.0..
Low-Water : When the level of humidification water is lower than limit on the humidity reservoir.
In every case, the Alarm lamp will be flash and audible alarm will also sound

 

Air circulation system

The new CHS-i1000 infant incubator adopts an Air Circulation System to maintain consistent air temperature and humidity in the hood and reduce radiant heat losses from the infant by flowing warm air between inner wall and outer wall with circular blower.

 

Humidity Reservoir

The humidity reservoir is removable.It makes it easier to replace used water with fresh water and to clean the reservoir.

 

Specification

Power source

220V, 50/60Hz

Power consumption

Heater:40VA Controller:60VA Humidity: 30VA Cabinet:50VA

Control Mode

Air/Skin Mode

Warm-Up time

Under 25min

Oxygen Concentration

19%~99%

Humidifier

Auto Control

Water Reservoir Capacity

1,500ml

Skin temperature

Display ranges:22~45 Control ranges: 34~37

Air temperature

Display ranges:5~50 Control ranges: 20~37

Humidity Control

Display ranges: 30%~90% Control ranges: 30%~90%

Dimension (W x H x D)

Hood: 830 x 480 x 500

Cabinet(Option) : 1,016 x 701(630~880: Option) x 642

Mattress : 686 x 30 x 369

Noise level in Hood

<47 Db(A)

Weight

135kg (Full Option)

Controller type

Microprocessor

Alarms(L.E.D)

Power fail, System fail, Sensor fail, Over temp fail, Air flow fail, Air temp. fail, Skin temp. fail, Low-water

PAYMENTS DETAILS

This supplier supports payments for offline orders
  • Telegraphic Transfer : T/T
Contact Payment Manager
  • Name : LEE, GYEONG-HA
  • Tel : 82-0221097846
  • Email : jake9518@jw-medical.co.kr

SHIPPING

Shipping from : Republic of Korea
  • 2477, Nambusunhwan-ro, Seocho-gu, Seoul, Republic of Korea, 서울특별시,
Can't find a valid Shipping method for supplier account. Please contact the pertaining representative for detailed information.
CHOONGWAE MEDICAL CO., LTD.

CHOONGWAE MEDICAL CO., LTD.

Seller_Mail
  • The person in charge

  • Telephone

    82-0221097846
  • Fax

    02-852-0565
  • Address

    2477, Nambusunhwan-ro, Seocho-gu, Seoul, Republic of Korea, 서울특별시,
  • Business Type :
    Manufacturer
  • Main Product :
  • Established :
    1972

CUSTOMER QUESTIONS & ANSWERS

0 / 4000

질문이 없습니다.

CUSTOMER REVIEWS (0)

At least 10~1000 characters.

0/ 1000

COMPARISON TO SIMILAR ITEMS more

  • Heavy Equipment Parts
  • LIVE CENTER (BP)
  • · Cylinder for offshore plants
  • SDA16/20/25/27
  • Automobile components
PLATINUMPLATINUM
CHOONGWAE MEDICAL CO., LTD. Seller's Store
  • Response Level
      41% ~ 50%
  • Supplier Level
      Less than 100 million (KRW)
  • Transaction Level
      less than 5
SUPPLIER BEST
  • CHS-2500
  • Infant Warmer
  • LED Operating Lights

Gobiz Korea, as the operator of mediation service or mail-order broker, shall not be held responsible for the sale order.
The responsibility on the ordering, delivery, and product refund belongs to the seller.

  • facebook
  • twitter
  • youtube
  • LinkedIn