IoT-S300E is one of world’s smallest model, of which persistent Stability and Temperature effect resistance besides various outputs, is much favored by customers in stocks raising, greenhouse, scientific projects, etc.. IOT-S300E is much favored by customers, whose application is HVAC, due to its easy management benefited from the ACDL and MCDL.
General Performance
Operating Temperature : -10 ~ 50℃
Operating Humidity : 0 ~ 95% RH (Non-condensing)
Storage Temperature : -30℃ ~ 70℃
CO₂ Measurement
Sensing Method : NDIR (Non-dispersive Infrared)
Measurement Range : 400 ~5,000ppm
Accuracy : ±50ppm ±5% of reading with ACDL Logic Condition
Response Time (1/e) : 120 seconds
Sampling Interval : 3 seconds
Electrical Data
Power Input : 4.75V ~ 5.50V (5.0V ± 5% Regulation)
Product Derivatives with Functions
Products |
Option List |
IoT-S300E
(H/W ACDL) |
Output: UART, I2C,
Calibration: H/W based MCDL & H/W based ACDL,
(ACDL function activated by low signal input to pin No. J12-7 or J13-11) |
IoT-S300EA
(S/W ACDL) |
Output: UART, I2C,
Periodic Automatic Calibration (ACDL) function is automatically started by installed S/W when every power on.. |
CONTACT US : sales@eltsensor.co.kr