Go to body Contents
Unbranded

Magnetic Contactor

  • Payment
    T/T
  • MOQ
    Negotiable
  • Country of sale
    World Wide
  • PRICE
    • FOB

      Depend on quantity

ITEM SPECIFICS

  • Brand
    Unbranded
    Model MC, TH
  • origin
    Republic of Korea
  • Size(Capacity)
    -
MC&TOR
Magnetic Contactor/Thermal Overload Relay
 
A switch for safely turning on or off the power of diverse electronics for power facilities such as a motor
 
 
TYPE MC9 MC12 MC18 MC22 MC32 MC40 MC48 MC50
IEC
60947
3 PHASE
SQUIRREL
CAGE
MOTOR
AC3 200~240V 2.5kW 11A 3.5kW 13A 4.5kW 18A 5.5kW 20A 7.5kW 32A 11kW 40A 11kW 48A 15kW 50A
380~440V 4kW 9A 5.5kW 12A 7.5kW 18A 11kW 20A 15kW 26A 18.5kW 35A 18.5kW 22kW 48A
500~550V 4kW 7A 7.5kW 12A 7.5kW 13A 15kW 22A 18.5kW28A 22kW 32A 22kW 40A 30kW 43A
690V 4kW 5A 7.5kW 9A 7.5kW 9A 15kW 18A 18.5kW 20A 22kW 23A 22kW 25A 30kW 28A
AC4 200~240V 1.5kW 8A 2.2kW 11A 3.7kW 18A 3.7kW 18A 4.5kW 20A 5.5kW 25A 7.5kW 30A 7.5kW 35A
380~440V 2.2kW 6A 4kW 6A 4kW 9A 5.5kW 13A 7.5kW 17A 11kW 24A 11kW 28A 15kW 32A
ITH AC1 25A 25A 40A 40A 50A 60A 70A 80A
ENDURANCE
(X10,000 TIMES)
ELECTRICAL 250 250 250 250 200 200 200 200
MECHANICAL 2500 2500 2500 2500 1500 1500 1500 1000
AUX. CONTACT(STANDARD) 1a1b 1a1b 1a1b 1a1b 2a2b 2a2b 2a2b 2a2b
AUX. CONTACT SIDE-ON AU1 AU1 AU1 AU1 AU1 AU1 AU1 AU1
HEAD-ON AU 2, AU 4 AU 2, AU 4 AU 2, AU 4 AU 2, AU 4 AU 2, AU 4 AU 2, AU 4 AU 2, AU 4 AU 2, AU 4
MOUNTING METHOD Screw and DIN Rail
DIMENSION(MM)(WXHXD) 44x78x86.8 44x78x86.8 44x78x86.8 44x78x86.8 66×82.6×94.6 66×82.6×94.6 66×82.6×94.6 92x122x117.3
MOUNTING
DIMENSION(MM)
(WXD) 30~35×48~59
35×60
30~35×48~59
35×60
30~35×48~59
35×60
30~35×48~59
35×60
30~35×48~59
35×60
30~35×48~59
35×60
30~35×48~59
35×60
100×50~60
100×60
APPLI-
CATION
CONTACTOR WITH DC-OPERATED COIL MD 9 MD 12 MD 18 MD 22 MD 32 MD 40 MD 48
REVERSING MC 9R MC 12R MC 18R MD 22R MC 32R MC 40R MC 48R MC 50R
SWITCH STANDARD MS 9 MS 12 MS 18 MS 22 MS 32 MS 40 MS 48 MS 50
REVERSING MS 9R MS 12R MS 18R MS 22R MS 32R MS 40R MS 48R MS 50R
PHASE LOSS PROTECTION MS 9K MS 12K MS 18K MS 22K MS 32K MS 40K MS 48K MS 50K
THERMAL
OVERLOAD
RELAY
STANDARD TH 22 TH 22 TH 22 TH 22 TH 40 TH 40 TH 40 TH 85
3 ELEMENTS TH 22/3 TH 22/3 TH 22/3 TH 22/3 TH 40/3 TH 40/3 TH 40/3 TH 85/3
SEPARATE MOUNTING TH 22H TH 22H TH 22H TH 22H TH 40H TH 40H TH 40H TH 85H
PHASE LOSS PROTECTION TK 22 TK 22 TK 22 TK 22 TK 40 TK 40 TK 40 TK 85
IEC 60947-1
CERTIFICATION KSC IEC 60947-4-1
UL 508
CE, TUV

 
TYPE MC 65 MC 75 MC 85 MC 100 MC 125 MC 150 MC 180 MC 220 MC 300 MC 400
IEC
60947
3 PHASE
SQUIRREL
CAGE
MOTOR
AC3 200~240V 18.5kW 65A 22kW 75A 25kW 80A 30kW 100A 37kW 125A 45kW 150A 55kW 180A 75kW 220A 90kW 300A 125kW 400A
380~440V 37kW 65A 37kW 75A 45kW 80A 55kW 100A 60kW 125A 75kW 150A 90kW 180A 132kW 220A 160kW 300A 200kW 400A
500~550V 33kW 60A 37kW 64A 45kW 75A 55kW 85A 60kW 90A 90kW 140A 110kW 120A 132kW 200A 160kW 250A 225kW 350A
690V 33kW 35A 37kW 42A 45kW 45A 55kW 65A 60kW 70A 90kW 100A 110kW 120A 132kW 150A 200kW 220A 250kW 300A
AC4 200~240V 11kW 50A 13kW 55A 15kW 65A 19kW 80A 22kW 93A 30kW 125A 37kW 150A 45kW 180A 55kW 220A 75kW 300A
380~440V 22kW 47A 25kW 52A 30kW 62A 37kW 75A 45kW 90A 55kW 110A 75kW 150A 90kW 180A 110kW 220A 150kW 300A
ITH AC1 100A 110A 135A 160A 160A 210A 230A 275A 350A 450A
ENDURANCE
(X10,000 TIMES)
ELECTRICAL 200 200 200 100 100 100 100 100 100 50
MECHANICAL 1000 1000 1000 500 500 500 500 500 500 500
AUX. CONTACT(STANDARD) 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b 2a2b
AUX. CONTACT SIDE-ON AU 1 AU 1 AU 1 AU 100 AU 100 AU 100 AU 100 AU 100 AU 100 AU 100
HEAD-ON AU 2, AU 4 AU 2, AU 4 AU 2, AU 4
MOUNTING METHOD Screw and DIN Rail Screw only
DIMENSION(MM)(WXHXD) 92x122
x117.3
92x122
x117.3
92x122
x117.3
100×157.4
×146.5
100×157.4
×146.5
120×166.8
×157
138x203
x181
138x203
x181
163x243
x198
163x243
x198
MOUNTING
DIMENSION
(MM)
(WXD) 100×50~60
100×60
100×50~60
100×60
100×50~60
100×60
80×100
90×125
80×100
90×125
100×125~130 45×190
120×190
45×190
120×190
50×210
60×220
145×225
50×210
60×220
145×225
APPLI-
CATION
CONTAC
TOR
WITH DC-
OPERATED COIL
REVERSING MC 65R MC 75R MC 85R MC 100R MC 125R MC 150R MC 180R MC 220R MC 300R MC 400R
SWITCH STANDARD MS 65 MS 75 MS 85 MS 100 MS 125 MS 150 MS 180 MS 220 MS 300 MS 400
REVERSING MS 65R MS 75R MS 85R MS 100R MS 125R MS 150R MS 180R MS 220R MS 300R MS 400R
PHASE LOSS PROTECTION MS 65K MS 75K MS 85K MS 100K MS 125K MS 150K MS 180K MS 220K MS 300K MS 400K
THERMAL
OVERLOAD
RELAY
STANDARD TH 85 TH 85 TH 85 TH 100 TH 100 TH 150 TH 220 TH 220 TH 400 TH 400
3 ELEMENTS TH 85/3 TH 85/3 TH 85/3 TH 100/3 TH 100/3 TH 150/3 TH 220/3 TH 220/3 TH 400/3 TH 400/3
SEPARATE
MOUNTING
TH 85H TH 85H TH 85H
PHASE LOSS PROTECTION TK 85 TK 85 TK 85 TK 100 TK 100 TK 150 TK 220 TK 220 TK 400 TK 400
IEC 60947-1
CERTIFICATION KSC IEC 60947-4-1
UL 508
CE, TUV
 
 
Characteristics

 
  • •Direct connection to a magnetic contactor
    Our thermal overload relays are conveniently connected to a magnetic contactor without any wire (applicable types : TH 22, 40, 85, 100, 150, 220, 400)

  • •Finger proof cover can be installed.
    Finger proof cover can be installed for electric conduction parts not to be connected to human body.
     * Finger proof cover is an option.

  • •Separation of power/operation part
    The main circuit and the operation part are separately designed and the operation part is commonly designed for TH 22, 40, 85, 100, 150 for improving safety.
Easy operation
3 steps current setting
The rated current can be set with a Philips or flat head screw driver.
Easy in setting Manual-Auto Reset
For the increased convenience of the user, you can select manual reset or automatic reset at your choice.
(Manual Reset) As shown on the right, turn the reset screw so that the arrow mark points to “H” and allow the screw to lift up.

(Automatic Reset) Push down the reset screw and turn it so that the arrow mark points to “A”.
Trip Indication
If the TOR is tripped, it descends 2~3mm and indicates the tripped condition. When testing manually, lift up the transparent cover and push (Transparent cover is to protect the careless adjustment after setting the contact current by knob).
Temperature compensation Bi-metal applied
Separate temperature compensation with the ambient temperature change is not necessary (Applied ambient temperature: -10°C ~ +40°C).
Strong operation part with Vibration Resistance (700g)

Separate mounting unit
In case of mounting the overload relays independently, the separate mounting kits are available for panel installation with rail or screw (Applied types: TH 22)
   
Ratings of Auxiliary Contact
 
Rated Operating Current
AC15(11) (AC coil load) DC13(11) (DC coil load)
110V 220V 550V 110V 110V
1.6 0.8 0.3 0.28 0.14
 
 
Combination with a Magnetic Contactor
 
Magnetic Contactor

Overload Relay

MC 9,12,18,22
TH(K) 22
MC 32,40,48
TH(K) 40
MC 50,65,75,85 TH(K) 85
MC 100,125
TH(K) 100
Magnetic Contactor

Overload Relay

MC 150
TH(K) 150
MC 180,220
TH(K) 220
MC 300,400
TH(K) 400
 
 
 
 
 
 
 


Note : We also have the Eletronic Over Current Relays(DPR) which can be combined with Magnetic Contactors.
(For more details, please refer to the parts for the Electronic Over Current Relays in catalog.)

PAYMENTS DETAILS

This supplier supports payments for offline orders
  • Telegraphic Transfer : T/T
Contact Payment Manager
  • Name : KIM, DUCK-HYUN
  • Tel : 82-0313343371
  • Email : gnstyle@e-daco.net

SHIPPING

Shipping from : Republic of Korea
  • 22-9 Pogok-ro 234beon-gil Pogok-eup Cheoin-gu, Yongin-si, Gyeonggi-do (17028)
Can't find a valid Shipping method for supplier account. Please contact the pertaining representative for detailed information.
DAE RYUK CO., LTD

DAE RYUK CO., LTD

www.e-daco.kr Seller_Mail
  • The person in charge

    Duckhyun Kim
  • Telephone

    82-313343371
  • Fax

    -
  • Address

    22-9 Pogok-ro 234beon-gil Pogok-eup Cheoin-gu, Yongin-si, Gyeonggi-do (17028)
Introduction
Daeryuk is protecting customers in 26 countries including Korea by specialized manufacturing and sales of industrial electronics and home appliances. DAERYUK also known as DACO (brand name) is the one of leaders in Korean low voltage industry since our establishment in 1978. Developing the ODP (Oil Dash Pot : overcurrent detector in hydraulic type circuit breaker), the core part of low voltage circuit breaker for the first time in Korea, DAERYUK started pioneering the LV industry. Thanks to our customer’s continuos support and encouragement, now DAERYUK is specialized in the production of LV components such as MCCB, ELCB, CONTACTOR, THERMAL RELAY, SMART CABINET PANEL, ATS and CIRCUIT PROTECTOR, ETC. Since we focused on not only domestic customers, but also overseas demand, we have strong business relationship with Japanese partners from early of 1990s in forms of OEM production. To make our customers satisfied we never delay creative innovation to R&D and quality control. Based on progressive technology, we strive to provide good value to our customers with top notched products. Thanks for being with us.
  • Business Type :
    Manufacturer
  • Main Product :
    Circuit Breaker (MCCB), Contactor
  • Established :
    1978-10-01
  • Total Annual Revenue :
  • Total Employees :
    101~500 people

R&D CERTIFICATE

CUSTOMER QUESTIONS & ANSWERS

0 / 4000

질문이 없습니다.

CUSTOMER REVIEWS (0)

At least 10~1000 characters.

0/ 1000

COMPARISON TO SIMILAR ITEMS more

  • No Items
PLATINUMPLATINUM
DAE RYUK CO., LTD Seller's Store
  • Response Level
      41% ~ 50%
  • Supplier Level
      Less than 100 million (KRW)
  • Transaction Level
      less than 5
SUPPLIER BEST
  • Magnetic Contactor
  • Circuit Protector
  • Molded Case Circuit Breaker