As the world’s smallest CO2 sensor module, T-200 Series sensors can be located outside the building as well as inside due to their robustness, Consistent Long-term Stability and Temperature change Effect Compensation.
Besides, their easier management are much favored by customers. T-200-3V Series support 3.3Voltage input and sleep mode function for low power consumption design.
General Performance
Operating Temperature : -20 ~ 60℃
Operating Humidity : 0 ~ 95% RH (Non-condensing)
Operating Environment : Residential, Commercial spaces
Storage Temperature : -30℃ ~ 70℃
CO₂ Measurement
Sensing Method : NDIR (Non-dispersive Infrared)
Measurement Range : 400 ~ 2,000(3,000/5,000/10,000ppm, 2%/3%/5%/10% are available)
Accuracy : ±50ppm ±3% of reading (±300ppm ± 3% of reading - 2%/3%/5%/10% models)
Response Time (1/e) : 40 seconds
Sampling Interval : 3 seconds
Electrical Data
Power Input : 3.2V ~ 3.55V
Current Consumption : Normal mode : 12mA, Peak : 180mA, Sleep: 0.3mA
Product Derivatives with Functions
Products |
Option List |
T-200L-3V (Low Power) |
Sleep mode is added on T-200-3V for Low power, which consume < 0.3mA |
T-200G-3V (99%Humidity) |
Resistance up to 99% Humidity is added on T-200-3V, for Application of bathroom |
T-200LG-3V |
Sleep mode + 99% Humidity |
T-200A-3V (ACDLS/W) |
Operate with ACDL S/W as default only for application of Residential Indoor Air Quality Monitoring which calibrate sensor every week by itself |