64 channel DXA Bone Densitometry
InAlyzer AIR uses 64 ch dual energy x-ray detector based on Fan Beam technology and obtains 64 rows of data per one x-ray irradiation, enabling acquisition of data of higher resolution in a shorter time, unlike pencil beam system that obtains 1 row of data per one x ray irradiation. Also the reliability and durability was enhanced by using an x ray generator that does not require fast switching between high energy and low energy, and the x ray detector that acquires high resolution data of high energy and low energy independently provides high-quality images.
InAlyzer AIR has an open design for the first time in the world, and this results in not only a chic design but also, by locating the moving axis to the center of the moving part, minimizing the shaking between the X ray generation and x ray detection section during the scan and, thereby, maintaining accuracy in the measurement result.
High resolution and fast measurement
By applying the energy-fixed x-ray generator, we minimized the failure rate, while the energy-independent high-resolution detector provides fast high resolution results.
Wide inside & Compact outside
Our own equipment technology maximized the scan are, minimizing the patient's movement and external size for space efficiency in hospitals.
Powerful & user-friendly Interface
In addition to high resolution images, it provides various image-processing tools and the user-friendly ROI (Region Of Interest) enables convenient and accurate use of the analysis. Also, the self-diagnosis allows the equipment to maintain its performance and produce precise results.
Excellent & Robust design
As a product of a national R&D project, the equipment features a chic design, including the world-first open of its kind, reduced rate of errors caused by vibration during scanning, and therefore, high levels of accuracy and precision.
Proven reliability
Our own DXA technology has been recognized and trusted by university hospitals and national research centers to which InAlyzer (Laboratory equipment) is supplied.
[Applications]
Orthopedic
Bone Mineral Density
Bone Mineral Contents
Bone area
Fat %
Lean &
T-score
Z-score
Half body composition analysis
[Specifications]
• Precision: less than 1% cv (1.0g/cm2)
• No. channel: 64
• Image resolution: 0.45 mm (on the bed surface)
• Scan area: 490 x 90 mm
• Scan time: AP spine: 30 sec.
Right/Left femur: 30 sec.
Right/Left Forearm: 30 sec.
L-Spine (Option): 60 sec.
LVA (Option): 90 sec.
Half body (Option): 180 sec.