Vibration mm/s | Noise dB(A, L) | ||
Accuracy | ±0.01mm/sec | Range(dB A) | 35 to 130dB |
Velocity Range | Up to 254mm/sec | Frequency Range | 20 to 16KHz |
Frequency Range | 2~200Hz(Basic 2~100Hz) | Range(dB L) | 65 to 140dB |
Sample Rate | 1024, 2048, 4096/sec/ch | Frequency Range | 2 to 200Hz |
Recording Time | 1, 2, 4, 8, 16sec | Operating Temp. | -40 to 85°C |
Resolution | 0.0038mm/sec | Recording Time | 1, 2, 4, 8, 16sec |
Calibration | Internal dynamic | Accuracy | ±10dB |
Trigger Value | 0.1 to 250mm/sec | Calibration | 94dB(B & K 4226) |
OLED Operating | -45 to 85°C | Trigger Value | 35 to 140dB(L) |
Electronic Operating | -45 to 85°C |
Battery | Memory | Basic Specification | |||
Rechargeable battery | Lithium-ion | Event storage time | File(KB) | Memory size | 4M, 8M(Option) |
Battery power on hours | 10 hours | 1sec | 17 | Weight | Vibration-45°C to +80°C |
Charging voltage | 9V | 2sec | 33 | Dimension | Noise 0°C to 40°C |
Charging hours | 6H | 4sec | 66 | 2.6kg | |
Workable temp | 0~45°C | 8sec | 132 | 180 x 100 x 85 | |
Charging temp. | -20~60°C | 16sec | 264 |