    Spirometer(Spiro LENIS / SL503) / USD 4800 / 10ea, Mouthpieces(1box/25ea)/ USD 470 / 10ea

  • Country of sale
    Europe, Asia, Africa, Americas, World Wide
  • PRICE
    • FOB

      USD 4,800.00

      (10 ea)

ITEM SPECIFICS

  • Brand
    SPIRO LENIS
    Model SL503
  • origin
    Republic of Korea
  • Size(Capacity)
    71(H) x 200(W) x 30(T) (Unit, mm)
  • Function
    Diagnostic spirometer
  • Weight
    242g (including internal battery)
  • Expiry Date
    5 years
  • Gender
    none
  • age-appropriate
    All ages
SPIRO LENIS Diagnostic spirometer SL503
Spiro-Lenis is designed for pulmonary function test. For a system, the microprocessor control the collection of the volume, and display of the graphic and numerical data.
The spirometer measures and calculates a long list of human respiratory function parameters.
For spirometry tests on patients of any age excluding babies and infants.
The spirometer is designed to be used by medical staff only, being supervised by a physician. Specific training in spirometry is recommended.
Bronchoconstriction test must be performed and supervised by qualified staff.
User must be familiarized with the functioning of the device before beginning to perform tests with patients.
Description of the Intended Use
The spirometer measures and calculates a long list of human respiratory function parameters.
Applicable Patients Profile
1) Age: Any age excluding babies and infants
2) Weight: Not relevant
3) Gender: Not relevant
4) Nationality: Multiple
5) Health condition: The patient need to take the Pulmonary Function Test
Intended User Profile
1) Age: Any age excluding babies and infants
2) Gender: Not relevant
3) Linguistic and cultural background: Not relevant
4) Level of education and professional competence : Graduate the education related to medical and medical staff
5) Experience : This device is designed to be used by medical staff only, being supervised by a physician. Specific training in spirometry is experienced.
6) Expert: Medical Staff
Specification
Product Name Diagnostic spirometer
Model/Series No. SL503
Brand Name SPIRO LENIS
Dimensions Device(Unit, mm) 200(W) x 71(H) x 30(T)
Weight 242g (including internal battery)
Display 4'' TFT LCD (800 X 480 resolution)
Flow measurement ±14L/s
Interface Touch pad, 1-power key
Data transmission USB 2.0
Memory Up to 1000 data
Volume accuracy ±3.0% or 0.05L
Flow accuracy ±5% or 10L/min(0.17L/s)
Parameters FVC, FEV0.5, FEV1, FEV3, FEV0.5/FVC, FEV1/FVC, FEV3/FVC, PEF, FEF25-75%, MEF25%, MEF50%, MEF75%, FIV, FIV1, FIV1/FIVC, FIV1/FVC, PIF, SVC, IV, ERV, IRV, MVV, RR, PRE/POST test
Operating Condition Temperature: -20℃ ~ 70 ℃, Humidity: 10% ~ 90%, Altitude: 70(700) ~ 106Kpa(1060mbar)
Storage Condition Temperature: -20℃ ~ 70 ℃, Humidity: 10% ~ 90%
Transportation Condition Temperature: -20℃ ~ 70 ℃, Humidity: 10% ~ 90%
Expected Service Life Time 5 years
Origin Republic of Korea
Features
· High performance PC software for spirometry (always included with free software upgrades)
· View and analyze tests as patients perform them with large, real time, easy-to-read display (Candle and Column of water display)
· Acquires, interprets and trends patient data for comprehensive view
· Simple, one-click print
How to use the device
Cautions
1) Please, check the connection of a mouthpiece and a connector. If the connection is not great, it can be lead to errors in spirometry.
2) At a time of using product, the user has a sufficient understand of a spirometry. An any user shall operate the device after sufficient readings of the components and operation.
3) If there is not anything on the screen at power-on of the Spiro-lenis, do not use the device with contacting the place of the purchase.
4) The new information shall be registered whenever patient information changes.
5) Any patient shall breathes with covering up the mouthpiece by mouth to avoid the leakage air.
6) Please, pay attention that there is a risk of over breathing during the test
7) If the data of a device are deleted after back up, all data on the device will not be backed up anymore due to the deleted data
8) Do not use acetone or ketone solvents for cleaning. Do not use sterilization equipment or steam cleaners.
9) For a decisions of a disinfection, it shall be complete depending on the state of an electric wire and a lead wire by user organization
10) The product you have purchased should not is disposed of as unsorted waste. Please utilize your local WEEE collection facilities for the disposal of this product.
Company Overview
JNBIO is a medical device company established in 2015.
The representative product is a diagnostic spirometer.
JNBIO aims to make respiratory diseases measurable and more treatable.
We provide cutting edge technology to enable the right decisions for patients, physicians and researchers around the world.
 

R&D CERTIFICATE

PAYMENTS DETAILS

This supplier supports payments for offline orders
  • Telegraphic Transfer : T/T
Contact Payment Manager
  • Name : JAESEOK LEE
  • Tel : 82-332632655
  • Email : lee@ejnbio.com

SHIPPING

Shipping from : Republic of Korea
  • 1 Kangwondaehak-gil, Chuncheon-si, Gangwon-do (24341)
JNBIO Co., Ltd.

JNBIO Co., Ltd.

www.ejnbio.com Seller_Mail
  • The person in charge

    JAESEOK LEE
  • Telephone

    82-332632655
  • Fax

    -
  • Address

    1 Kangwondaehak-gil, Chuncheon-si, Gangwon-do (24341)
Introduction
JNBIO aims to make respiratory diseases measurable and more treatable. We provide cutting edge technology to enable the right decisions for patients, physicians and researchers around the world. - Spirometer : Spiro LENIS
  • Business Type :
    Manufacturer
  • Main Product :
    Spirometer, HRV-meter
  • Established :
    2015-09-03
  • Total Annual Revenue :
    6 million to 10 billion (KRW)
  • Total Employees :
    Less than 5

R&D CERTIFICATE

CUSTOMER QUESTIONS & ANSWERS

0 / 4000

질문이 없습니다.

CUSTOMER REVIEWS (0)

At least 10~1000 characters.

0/ 1000

COMPARISON TO SIMILAR ITEMS more

  • No Items
MEMBER
JNBIO Co., Ltd. Seller's Store
  • Response Level
      more than 70%
  • Supplier Level
      1 million to 10 billion(KRW)
  • Transaction Level
      less than 5
SUPPLIER BEST
  • SPIRO FLO Diagnostic spirometer SF100