Go to body Contents
SPIRO FLO

SPIRO FLO Diagnostic spirometer SF100

  • Payment
    T/T
  • MOQ
    100 ea
  • Supply Ability
    10,000 ea per One-Time
  • Supply Details
    Customization ,  Sample Order

    Spirometer(Spiro FLO/ SF100) / USD 3800 / 10ea, Mouthpieces(1box/25ea)/ USD 470 / 10ea

  • Country of sale
    Europe, Asia, Africa, Americas, World Wide
  • PRICE
    • FOB

      USD 3,800.00

      (10 ea)

ITEM SPECIFICS

  • Brand
    SPIRO FLO
    Model SF100
  • origin
    Republic of Korea
  • Size(Capacity)
    190(H) x 46(W) x 46(T) (Unit, mm)
  • Function
    Diagnostic spirometer
  • Weight
    200g
  • Expiry Date
    5 years
  • Gender
    none
  • age-appropriate
    All ages
SPIRO FLO Diagnostic spirometer SF100
SPIRO FLO is designed for pulmonary function test. For a system, the microprocessor control the collection of the volume, and display of the graphic and numerical data.
The spirometer measures and calculates a long list of human respiratory function parameters.
For spirometry tests on patients of any age excluding babies and infants.
The spirometer is designed to be used by medical staff only, being supervised by a physician.
Specific training in spirometry is recommended. Bronchoconstriction test must be performed and supervised by qualified staff.
User must be familiarized with the functioning of the device before beginning to perform tests with patients.
Description of the Intended Use
The spirometer measures and calculates a long list of human respiratory function parameters.
Applicable Patients Profile
1) Age: Any age excluding babies and infants
2) Weight: Not relevant
3) Gender: Not relevant
4) Nationality: Multiple
5) Health condition: The patient need to take the Pulmonary Function Test
Intended User Profile
1) Age: Any age excluding babies and infants
2) Gender: Not relevant
3) Linguistic and cultural background: Not relevant
4) Level of education and professional competence : Graduate the education related to medical and medical staff
5) Experience : This device is designed to be used by medical staff only, being supervised by a physician. Specific training in spirometry is experienced.
6) Expert: Medical Staff
Specification
Product Name Diagnostic spirometer
Model/Series No. SF100
Brand Name SPIRO FLO
Dimensions Device(Unit, mm) 190(H) x 46(W) x 46(T)
Weight 200g
Flow measurement ±14L/s
Data transmission USB 2.0
Memory Up to 1000 data
Volume accuracy ±3.0% or 0.05L
Flow accuracy ±5% or 10L/min(0.17L/s)
Parameters FVC, FEV0.5, FEV1, FEV3, FEV0.5/FVC, FEV1/FVC, FEV3/FVC, PEF, FEF25-75%, MEF25%, MEF50%, MEF75%, FIV, FIV1, FIV1/FIVC, FIV1/FVC, PIF, SVC, IV, ERV, IRV, MVV, RR, PRE/POST test
Expected Service Life Time 5 years
Origin Republic of Korea
Features
· High performance PC software for spirometry (always included with free software upgrades)
· View and analyze tests as patients perform them with large, real time, easy-to-read display (Candle and Column of water display)
· Acquires, interprets and trends patient data for comprehensive view
· Simple, one-click print
Product Disposal
The product you have purchased should not be disposed of as unsorted waste. Please utilize your local WEEE collection facilities for the disposal of this product.
Device INSTRUCTIONS
Before conducting any spirometry testing, install SPIRO Q on a Windows-compatible computer.
Once SPIRO Q has been installed connect the SPIRO FLO device to the computer via, depending on which version is being used.
Warnings, Cautions and Notes
This device designed to minimize risks from any program error.
1) Do not use the device in area where has a risk of flammable anesthetics or solvents that may explode.
2) All information and troubleshooting for overwhelming the hard situation, which is included in the instructions for use, shall be correctly red before using SPIRO FLO. And then, the device shall be used by any user.
3) Be well informed of the Instructions for use regarding to any risk such as an electric shock, power, and then use the device
For this device repair and detail specification, refer to the service manual please.
4) All shall be handled with more care to reduce the possibility of a suffocation by tangling or twisting by the device when controlling of the patient
5) If a main-body and accessories of the SPIRO FLO are placed on anywhere, please be careful that it may drop on the patient. If any users suddenly lift the device, please be careful that the power or other cable may come out of the device.
6) Do not use the device during magnetic resonance imaging (MRI) scanning. Induced current may makes to create the fire.
7) When the SPIRO FLO is used, there is electric magnetic interference.
Please, use the device with control the alarm volume at use.
8) Do not place the device on the electric equipment. Because the electric equipment can affect to the device during operation.
9) Do not use the device in humid areas or with the wet hands.
10) Do not place the device near somethings, which contains liquid. The liquid may spill on the device and it could generate the malfunction or failure.
11) Operation Failure – If it is damaged due to an installation step or short circuit, please contact the JNBIO Co., Ltd.
12) If the sensor is damaged, please immediately stop to use the device for patient safety.
13) If any users have some questions or need help, please see the manual first and contact with JNBIO Co., Ltd.
Cautions
1) Please, check the connection of a mouthpiece and a connector. If the connection is not great, it can be lead to errors in spirometry.
2) At a time of using product, the user has a sufficient understand of a spirometry. An any user shall operate the device after sufficient readings of the components and operation.
3) If there is not anything on the screen at power-on of the SPIRO FLO, do not use the device with contacting the place of the purchase.
4) The new information shall be registered whenever patient information changes.
5) Any patient shall breathes with covering up the mouthpiece by mouth to avoid the leakage air.
6) Please, pay attention that there is a risk of over breathing during the test
7) If the data of a device are deleted after back up, all data on the device will not be backed up anymore due to the deleted data
8) Do not use acetone or ketone solvents for cleaning. Do not use sterilization equipment or steam cleaners.
9) For a decisions of a disinfection, it shall be complete depending on the state of an electric wire and a lead wire by user organization
10) The product you have purchased should not is disposed of as unsorted waste. Please utilize your local WEEE collection facilities for the disposal of this product.
Company Overview
JNBIO is a medical device company established in 2015.
The representative product is a diagnostic spirometer.
JNBIO aims to make respiratory diseases measurable and more treatable.
We provide cutting edge technology to enable the right decisions for patients, physicians and researchers around the world.
 

R&D CERTIFICATE

PAYMENTS DETAILS

This supplier supports payments for offline orders
  • Telegraphic Transfer : T/T
Contact Payment Manager
  • Name : JAESEOK LEE
  • Tel : 82-332632655
  • Email : lee@ejnbio.com

SHIPPING

Shipping from : Republic of Korea
  • 1 Kangwondaehak-gil, Chuncheon-si, Gangwon-do (24341)
JNBIO Co., Ltd.

JNBIO Co., Ltd.

www.ejnbio.com Seller_Mail
  • The person in charge

    JAESEOK LEE
  • Telephone

    82-332632655
  • Fax

    -
  • Address

    1 Kangwondaehak-gil, Chuncheon-si, Gangwon-do (24341)
Introduction
JNBIO aims to make respiratory diseases measurable and more treatable. We provide cutting edge technology to enable the right decisions for patients, physicians and researchers around the world. - Spirometer : Spiro LENIS
  • Business Type :
    Manufacturer
  • Main Product :
    Spirometer, HRV-meter
  • Established :
    2015-09-03
  • Total Annual Revenue :
    6 million to 10 billion (KRW)
  • Total Employees :
    Less than 5

R&D CERTIFICATE

CUSTOMER QUESTIONS & ANSWERS

0 / 4000

질문이 없습니다.

CUSTOMER REVIEWS (0)

At least 10~1000 characters.

0/ 1000

COMPARISON TO SIMILAR ITEMS more

  • No Items
MEMBER
JNBIO Co., Ltd. Seller's Store
  • Response Level
      41% ~ 50%
  • Supplier Level
      1 million to 10 billion(KRW)
  • Transaction Level
      less than 5
SUPPLIER BEST
  • SPIRO LENIS  Diagnostic spirometer SL503